Company News

Auto AC non-cooling: checks & common faults

Sensory Inspection Method

Automotive Air Conditioning Inspection and Common Faults (English Translation)

1. Compressor Operation Status

① Check if the drive belt is broken or loose. A loose drive belt will slip, accelerate wear, and fail to transmit power.

② Check for abnormal noise inside the compressor. Noise may be caused by damaged internal parts, and internal wear will result in ineffective compression.

③ Check if the compressor clutch is slipping.


2. Condenser and Fan Status

① Check if the condenser fins are covered with dust. Dust accumulation on the condenser fins will significantly reduce condensation efficiency.

② Check if the condenser fan operates normally.


3. Blower Fan Operation Status

Operate the blower at three speeds ("Low, Medium, High"). If there is abnormal noise or poor motor operation, repair or replace the blower immediately; otherwise, the air supply will be insufficient.


4. Refrigerant Level Inspection

① Observe through the sight glass: a large number of bubbles indicate insufficient refrigerant. If no bubbles are visible even after cooling the condenser with water, the refrigerant is overfilled.

② Check for oil stains at connections and joints. Oil stains at connections or joints indicate refrigerant leakage. Retighten or replace relevant parts (leak detectors can be used for verification).


5. HVAC Valve/Heat Control Damper and Air Damper Adjustment

Check if the HVAC valve or heat control damper is closed and if other dampers adjust normally.

(Note: If the compressor clutch fails to engage, the blower fan or condenser fan does not operate, first inspect the relevant electrical system, including relays, sensors, circuit open/short circuits, and control units.)


Gauge Detection Method

This method uses a set of refrigerant pressure gauges to locate faults.

1. Close the high-pressure and low-pressure valves of the pressure gauge.

2. Connect the refrigerant charging hoses to the corresponding service valves of the compressor in a shutdown state.

3. Use the refrigerant pressure in the refrigeration system to purge air from the hoses. At this point, the high-pressure and low-pressure readings should be balanced (approximately 6kg/cm²).

4. Start the engine and maintain a speed of 1500rpm. Set the blower to the highest speed, the air conditioning to maximum cooling, and switch to "recirculation" mode.

Normal Pressure Readings

| Refrigerant Type | Low-Pressure Side | High-Pressure Side |

|------------------|-------------------|--------------------|

| R-134a           | 1.5-2.5kg/cm²     | 14-16kg/cm²        |

| R-12             | 1.5-2.0kg/cm²     | 13-15kg/cm²        |


Gauge Reading Fault Analysis and Solutions

1. Both high and low-pressure readings lower than standard; bubbles visible in the sight glass**

- Causes: Refrigeration cycle leakage; insufficient refrigerant replenishment.

- Solution: Detect leaks with a leak detector, repair the leakage point, and replenish refrigerant to the specified level.


2. Low-pressure side shows negative pressure; high-pressure side lower than normal; temperature difference before and after the receiver/dryer; frost on the pipeline after the receiver/dryer (in severe cases)

- Causes: Clogged expansion valve or low-pressure pipeline; clogged receiver/dryer or high-pressure pipeline; leaking expansion valve sensing bulb; fully closed needle valve.

- Solution: Clean or replace relevant components and the receiver/dryer. Replace the expansion valve if the sensing bulb is leaking.


3. Both high and low-pressure readings higher than standard; discharge side of the condenser not hot

- Cause: Overfilled refrigerant.

- Solution: Release excess refrigerant to reach the standard pressure.


4. Both high and low-pressure readings higher than normal; high-pressure side drops sharply to approximately 2kg/cm² after shutdown

- Cause: Air mixed in the refrigeration cycle (insufficient evacuation or air ingress during charging).

- Solution: Evacuate and recharge refrigerant. If the problem persists, replace the receiver/dryer and compressor oil.


5. Both high and low-pressure readings higher than normal; frost or heavy condensation on the low-pressure pipeline

- Causes: Faulty expansion valve (needle valve open too wide); disconnected expansion valve sensing bulb from the evaporator.

- Solution: Inspect and reconnect the sensing bulb or replace the expansion valve.


6. Low-pressure side pressure high; high-pressure side pressure low; pressure on both sides balances immediately after shutdown

- Cause: Damaged compressor valves, pistons, or piston rings resulting in ineffective compression.

- Solution: Replace the compressor.


7. Fluctuating pressure readings on both high and low-pressure sides

- Cause: The dryer is saturated and cannot remove moisture from the refrigerant, leading to ice blockage in the expansion valve needle valve. When refrigerant circulation stops, the ice thaws and refreezes repeatedly.

- Solution: Replace the receiver/dryer and compressor oil, then evacuate and recharge refrigerant.


Common Faults of Automotive Air Conditioning

Fault 1: Compressor Malfunction

Automotive air conditioning compressors are equipped with a clutch, which must engage for the compressor to operate. If the compressor is damaged and fails to engage, the air conditioning will not cool. If the refrigerant level is sufficient but the system still does not cool, the compressor may have stopped working, requiring repair or replacement.


Fault 2: Abnormal Noise from Air Conditioning

When abnormal noise is detected, identify its source:

- Internal noise (from the center console): Usually caused by air or moisture in the refrigerant, which produces noise during evaporation and expansion.

- External noise (near the compressor): Typically originates from the compressor itself.

Most air conditioning noise is due to air and moisture contamination in the refrigerant.


Fault 3: Classification of Abnormal Noise

- If noise persists after refrigerant evacuation and recharge and is located near the compressor, the compressor’s internal mechanical structure may be damaged.

- If noise recurs after a period and comes from the center console, it is mostly caused by reduced efficiency of the receiver/dryer.


Fault 4: Refrigerant Leakage

When the air conditioning is turned on, a large amount of white, pungent gas (vaporized refrigerant) blowing from the air outlets indicates a leak in the evaporator inside the center console.

- Solution: Replace the evaporator.